부품 정보
Surface treatment black enamel
TXT
묘사:
Ignition System Distributor
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Iron, cast
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Rigid coupled
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Ignition coil
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
Between 1.061 inches and 1.062 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
5.250 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus resistant and submersible
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Tongue
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
An indication of whether or not a distributor cap is included.ARFE
Distributor Cap:
Included
MRC:
The means of attaching the item.AXGY
Mounting Method:
Base
MRC:
The number of impulses produced by one complete revolution.AXRT
Impulse Quantity Per Revolution:
6
MRC:
Indicates the type of ignition for which the item is designed.AXRW
Ignition Type For Which Designed:
Single
MRC:
Indicates the type of terminals included in the distributor cap to accommodate the spark plug wires.AYEN
Secondary Terminal Type:
Threaded
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter of the spark plug terminal accommodation.AYEP
Spark Plug Terminal Accommodation Thread Series:
Unef
MRC:
Indicates the type of terminals included in the distributor cap to accommodate the coil wire.AYER
Coil Terminal Type:
Threaded
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter of the coil terminal accommodation.AYET
Err Default:
Err default
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter of the coil terminal accommodation.AYET
Coil Terminal Accommodation Thread Series:
Unef
MRC:
The length of a straight line which passes through the center of the coil terminal accommodation,which bound the crest of an external thread or the root of an internal thread,and terminates at the circumference.AYEX
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the coil terminal accommodation,which bound the crest of an external thread or the root of an internal thread,and terminates at the circumference.AYEX
Coil Terminal Accommodation Thread Diameter:
0.750 inches
MRC:
Indicates the type of primary terminal accommodation/s/ on the item.AYEY
Primary Terminal Accommodation Type:
Screw
MRC:
The means by which the spark advance is controlled.AYKD
Spark Advance Control Method:
Centrifugal
MRC:
The maximum number of degrees the item is advanced.AYKF
Maximum Advance Deg:
20.0
MRC:
The number of contact sets incorporated in the unit.AYKN
Contact Set Quantity:
1
MRC:
The revolutions per minute of the item at maximum advance.AYLF
Rpm At Maximum Advance:
1800.0
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Hole
MRC:
A designation indicating the diameter-pitch combination and the number of threads per measurement scale applied to a series of diameters of a primary terminal accommodation.BYPP
Primary Terminal Accommodation Thread Series:
Unc
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Radio interference shielding
MRC:
The means by which the spark is transferred from the rotor to the spark plug terminals.CPWB
Spark Distribution Method:
Gap
MRC:
The length of a straight line which passes through the center of a spark plug terminal accommodation which would bound the crest of an external thread or the root of an internal thread.CPWC
Spark Plug Terminal Accommodation Thread Diameter:
0.625 inches
MRC:
The number of screw threads on the spark plug terminal accommodation per linear inch,including incomplete threads,on a line parallel to the thread axis.CPWD
Spark Plug Terminal Accommodation Thready Qty Per Inch (tpi):
24
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis.CPWF
Err Default:
Err default
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis.CPWF
Coil Terminal Accommodation Thready Qty Per Inch (tpi):
20
MRC:
A measurement of the length of a straight line which passes through the center of a coaxial cylinder in plan view which would bound the crest of an external thread or the root of an internal thread.CPWH
Primary Terminal Accommodation Thread Diameter:
0.250 inches
MRC:
The number of screw threads on the primary terminal accommodation per linear inch,including incomplete threads,on a line parallel to the thread axis.CPWJ
Primary Terminal Accommodation Thready Qty Per Inch (tpi):
20
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Enamel, black