MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
4.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.312 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The means of attaching the item.ADJH
Mounting Method:
Flange type for panel
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Aluminum plated
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Cam actuated and repeat cycle
MRC:
The means used to operate the item.APHE
Operation Method:
Electronic operated
MRC:
Indicates the type of timer provided.APPS
Timer Type:
Electrical
MRC:
An indication of whether or not a direct current operated clutch is included.AQZD
Dc Operated Clutch:
Not included
MRC:
An indication of whether or not an automatic electric circuit control switch is included.ARAE
Automatic Electric Circuit Control Switch:
Included
MRC:
The total electrical voltage in volts,of the control switch.ARAF
Control Switch Voltage In Volts:
125.0 or 250.0
MRC:
The amount of current for which the item is designed.ARAG
Current Rating:
5.000 amperes or 15.000 amperes
MRC:
The physical location of the control switch outlet tap.ARAH
Control Switch Outlet Tap Location:
On frame
MRC:
An indication of whether or not an interval expriation signalling device is included.ARAJ
Interval Expiration Signalling Device:
Not included
MRC:
An indication of whether or not an independently operated clock is included.ARCR
Independently Operated Clock:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
110.0
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0