부품 번호 H45V18130-950

Safety Relief Valve

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
h45v18130-950
비무장화:
No
수명:
측정 단위:
NIIN:
002894360

부품 정보
W/lifting lever

NSN
국가 주식 번호:
4820-00-289-4360 4820002894360
TXT
묘사:
Safety Relief Valve
INC
INC
아이템 이름 코드:
05488
MRC:
The means of closing the item when inlet pressure decreases.ADSU
Disk Loading Method:
Spring
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
12810.0 pounds per hour
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
12 1st end
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
8 2nd end
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
330.0 degrees fahrenheit single response
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Round with holes 1st end
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Round with holes 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange 2nd end
MRC:
The minimum to maximum pressures at which the item may be set to open.CQCY
Adjustable Pressure Range:
+25.0/+29.0 pounds per square inch
MRC:
The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
Outside Diameter:
10.500 inches 1st end
MRC:
The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
Outside Diameter:
9.000 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
Bolt Hole Diameter:
0.688 inches 1st end
MRC:
The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
Bolt Hole Diameter:
0.750 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
Bolt Circle Diameter:
7.500 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
Bolt Circle Diameter:
8.875 inches 1st end
MRC:
The design of the flange face.CWDF
Flange Face Design:
Raised straight 1st end
MRC:
The design of the flange face.CWDF
Flange Face Design:
Raised straight 2nd end
MRC:
A nominal measurement from the bottom to the top surface of a raised face,in distinction from depth.CWDH
Raised Face Height:
0.438 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of a raised face,and terminates at the circumference.CWDL
Raised Face Diameter:
6.188 inches 2nd end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel seat
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel stem
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Angle
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.TMQY
Furnished Items And Quantity:
1 sight gage

{lang[cimilar]} Safety Relief Valves

« Nonpowered Valves {lang[catalog]}
지금 비교»
맑다 | 숨기다