부품 번호 DB102202

Reactor-transformer

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 4944.719 and 6466.171 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
db102202
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
012485938

부품 정보
Weapon system essential

NSN
국가 주식 번호:
5950-01-248-5938 5950012485938
TXT
묘사:
Reactor-transformer
INC
INC
아이템 이름 코드:
02918
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
32 3rd component single primary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
4 3rd component 1st secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
48 3rd component 2nd secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
500 4th component single secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
7 1st component single winding
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
1 4th component single primary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
105 2nd component single winding
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
12 3rd component 3rd secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
25 3rd component 4th secondary
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.800 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.500 inches single mounting facility single center group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
10.00 microhenries 1st component single winding
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
90.00 microhenries 2nd component single winding and 3.10 millihenries 2nd component single winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
20.0 kilohertz 2nd component
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
20.0 kilohertz 3rd component
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
20.0 kilohertz 4th component
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz 1st component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase 3rd component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase 4th component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield grounded to terminal 3rd component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.300 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.010 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.630 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
C5b acft; wsd: aircraft, galaxy c-5
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical 1st component single winding and winding turns 1st component single winding
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical 3rd component 1st secondary and winding turns 3rd component 1st secondary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical 3rd component 2nd secondary and winding turns 3rd component 2nd secondary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical 3rd component 3rd secondary and winding turns 3rd component 3rd secondary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical 3rd component 4th secondary and winding turns 3rd component 4th secondary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical 3rd component single primary and winding turns 3rd component single primary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical 2nd component single winding and winding turns 2nd component single winding
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns 4th component single primary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns 4th component single secondary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary 3rd component and 6 secondary 3rd component
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary 4th component and 1 secondary 4th component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00200 inches american wire gage 1st component single winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00500 inches american wire gage 4th component single secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01594 inches american wire gage 3rd component 3rd secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01594 inches american wire gage 3rd component 4th secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01594 inches american wire gage 3rd component 1st secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01594 inches american wire gage 3rd component 2nd secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.02257 inches american wire gage 2nd component single winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.02535 inches american wire gage 3rd component single primary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.02535 inches american wire gage 4th component single primary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
29.0 amperes dc 2nd component single winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
30.0 amperes dc 1st component single winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.046 3rd component single primary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.120 3rd component 3rd secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.132 3rd component 1st secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.240 3rd component 4th secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.760 3rd component 2nd secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
14.000 4th component single secondary
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
0.10 ac volts 1st component single winding
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
15.60 ac volts 3rd component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
2.50 ac volts 3rd component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
20.00 ac volts 3rd component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
2.00 ac volts 2nd component single winding
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
30.00 ac volts 3rd component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
7.48 ac volts 3rd component 3rd secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
28 turret

{lang[cimilar]} Reactor-transformers

« Coils and Transformers {lang[catalog]}
지금 비교»
맑다 | 숨기다