MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.200 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.350 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.100 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.020 inches
MRC:
The maximum amount of electrical energy that can be expended by an item.AEHX
Maximum Power Dissipation Rating:
0.25 watts
MRC:
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
Ambient Tempurature At Full Rated Power:
25.0 degrees celsius
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
125.0 degrees celsius
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-15.0 degrees celsius 4th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-30.0 degrees celsius 3rd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-45.0 degrees celsius 2nd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-55.0 degrees celsius 1st resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
0.0 degrees celsius 5th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
100.0 degrees celsius 8th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
125.0 degrees celsius 9th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
50.0 degrees celsius 6th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
75.0 degrees celsius 7th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
689.3 ohms 1st resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
722.7 ohms 2nd resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
776.1 ohms 3rd resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
1.1136 kilohms 6th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
1.2339 kilohms 7th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
1.3603 kilohms 8th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
1.4925 kilohms 9th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
833.2 ohms 4th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
893.5 ohms 5th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-1.0/+1.0 all resistance-temperature points
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encapsulated
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
0.004 cubic inches
MRC:
The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.CQWD
Zero Power Resistance:
1.000 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.CRQJ
Zero Power Resistance Tolerance In Percent At Reference Temp:
-1.0/+1.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rod
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
16224-985824 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead