부품 번호:
7862-012revapctd87
MRC:
A measurement of the pipe size the item will accommodate.AAAR
Pipe Size Accommodated:
1.500 inches 1st end
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
150.0 degrees fahrenheit 2nd response
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
550.0 degrees fahrenheit 1st response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Streamlined with two brazing ring (pipe) 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal pipe 1st end
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
1000.0 pounds per square inch 2nd response
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
300.0 pounds per square inch 1st response
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy seat
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b61 assn standard single material response body
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b61 assn standard single material response flow control device
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Steam 1st response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water-oil-gas 2nd response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight thru