TXT
묘사:
Alternating Current Motor
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.188 inches single end
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.094 inches single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.875 inches single end
MRC:
A measurement of the longest dimension of a keyway,in distinction from width.AFYS
Keyway Length:
1.375 inches single end
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Fan cooled
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Nema
MRC:
A designation indicating the frame size by which the item is identified.CNMM
Frame Size Designation:
145t
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
1.500 horsepower output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
2.250 inches single end
MRC:
The distance between the center of the shaft to the mounting surface.CWDM
Shaft Center To Mounting Surface Distance:
3.500 inches single end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
5.000 inches
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
1800.0 single no load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
5.500 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
200.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A9 single style single end
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input