TXT
묘사:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
18
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Screw
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Amperes
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
10
MRC:
A measurement of the longest dimension of a mounting flange, in distinction from width.ADMG
Mounting Flange Length:
3.280 inches
MRC:
A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
Mounting Flange Width:
3.130 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum alloy
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 4-40 nc-2 mtg studs spaced 2.250 in. C to c
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
125.0 volts
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+0.0/+10.0
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the main contact/s/.APDY
Main Contact Form Arrangement:
1a
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
Main Contact Arrangement:
1 pole, double throw, both positions maintained
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Ac
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
5.0 amperes
MRC:
The rated power that the main contact/s/ can safely consume or provide.APED
Err Default:
Err default
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
0.050
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+10.0 amperes
MRC:
The cycles per second /hertz/ of current of the meter movement.APML
Meter Movement Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Flush
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
A measurement of the longest dimension of a meter body behind the mounting flange, in distinction from width.APSX
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the meter body behind the mounting flange, in distinction from thickness.APSY
Meter Body Width Behind Mounting Flange:
2.800 inches
MRC:
A measurement between the mounting flange and the face of the item, in distinction from height.APTN
Meter Depth To Mounting Flange:
5.500 inches