부품 정보
High and low setpointer adjustments
TXT
묘사:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
17
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Screw
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Amperes
MRC:
A measurement of the longest dimension of a mounting flange, in distinction from width.ADMG
Mounting Flange Length:
3.280 inches
MRC:
A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
Mounting Flange Width:
3.130 inches
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
Cubic Measure:
65.089 cubic inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four no. 4-40 unc-2a threaded stud placed in a rectangular configuration; c to c distance between mtg facilities 2.250 inches by 2.250 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
125.0 volts
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
-75.0/+75.0
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the main contact/s/.APDY
Main Contact Form Arrangement:
1c
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Ac
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
5.0 amperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Ac
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
115.000
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Semiflush
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
5.500 inches
MRC:
The length of a straight line which passes through the center of the meter body behind the mounting flange, and terminates at the circumference.APSW
Meter Body Diameter Behind Mounting Flange:
2.800 inches