TXT
묘사:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, corrosion resisting
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Tee
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Gas, noncorrosive and liquid, noncorrosive
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
0.250-18 npt
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACMQ
Second End Thread Size And Series/type Designator:
0.125-27 npt
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
Second End Thread Direction:
Right-hand
MRC:
Indicates whether or not the third end is identical with first or second end.ACMX
Third End Relationship With Preceding Ends:
Identical with second end
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
3
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+150.0/+850.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
325.0 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included