Control outline magnetic amplifier temperature control
TXT
묘사:
Indicating Temperature Control
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+160.0 degrees fahrenheit
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Back
MRC:
The minimum and maximum operating limits of the item.ASXT
Operating Range:
Max operating temp is 340 degrees f for 10 minutes or 250 degrees f for 30 minutes
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Panel
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
3.110 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
4.750 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Max inoperative ambient temp is 3oo degrees f; temp regulating deadband locked at 40 degrees f, fixed 85 degrees f; setting +/- 3 degrees f locked, +/- 5 degrees f fixed; resistor p/n 30050; no thermistor; weight 2.0 lbs max
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0