TXT
묘사:
S Electrical Insulation Sleeving
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius and 135.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant and flame resistant and solvent resistant
Main Body Inside Diameter:
0.690 inches after unrestricted recovery
Main Body Inside Diameter:
1.200 inches as supplied
First Branch Inside Diameter:
0.180 inches after unrestricted recovery
First Branch Inside Diameter:
0.500 inches as supplied
Second Branch Inside Diameter:
0.180 inches after unrestricted recovery
Second Branch Inside Diameter:
0.500 inches as supplied
Third Branch Inside Diameter:
0.180 inches after unrestricted recovery
Third Branch Inside Diameter:
0.500 inches as supplied
Main Body Wall Thickness:
0.090 inches after unrestricted recovery
Main Bodylength:
3.500 inches after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1000 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyolefin, rt-1304, raychem corp
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic, polyolefin, rt-1304, raychem corp