TXT
묘사:
Electronic Control Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.200 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.695 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.000 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
Not rated
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
Not rated
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
Not rated
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
Not rated
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
Not rated
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
Not rated
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
Not rated
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Solder lug bottom
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 1st voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 2nd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 2nd voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 1st voltage
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Roll computer, automatic flight control system