TXT
묘사:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
5
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Amperes
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
60
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Shock proof and vibration proof and waterproof and temperature resistant
MRC:
The hue or tint of the light emitted from that portion of the item which surrounds the inscription on the item.AETT
Inscription Background Color:
White
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Mtd by three 0.140 in. Diameter mtg holes spaced 120 degrees apart on a 1.580 in. Radius
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
100.0 volts
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+0.0/+12.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
Main Contact Arrangement:
1 pole, single throw, both positions maintained
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
Between 10.0 milliamperes and 25.0 milliamperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
0.050
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+12.0 amperes
MRC:
An indication of the direction of the meter movement reading range.APGT
Meter Movement Range Direction:
Left to right
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Flush
MRC:
An indication of the specific condition that causes the contacts to close.APMT
Contact Closing Condition:
Increase value
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Coil
MRC:
The means by which the item is released.APNT
Release Method:
Manual and electromagnetic
MRC:
The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.APTE
Mounting Flange Diameter:
3.590 inches
MRC:
The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
Meter Body Diameter:
2.630 inches
MRC:
A measurement between the mounting flange and the face of the item, in distinction from height.APTN
Meter Depth To Mounting Flange:
1.820 inches