TXT
묘사:
Electrical Solenoid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical frame
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.156 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.312 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.250 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.250 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.144 inches
MRC:
A measurement taken at right angles to the length of the mounting base,in distinction from thickness.AEXW
Mounting Base Width:
1.656 inches
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
0.509 inches
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
0.500 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
A measurement of the opposition to the flow of direct or alternating current.APCC
Electrical Resistance:
14.00 ohms
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
End opposite actuator
MRC:
The value of electrical energy for which the item is rated.ARQE
Electric Power Rating:
13.00 watts
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
13.8 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Pull
MRC:
The amount of linear force delivered.CNXW
Linear Force Delivered:
3.00 pounds
MRC:
Indicates the type of means provided for connection of the power takeoff.CNXX
Power Takeoff Connection Type:
Slotted-drilled
MRC:
The maximum linear travel from the de-energized to the energized position.CNYD
Energizing Stroke Maximum Length:
0.150 inches
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead