MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.ACSY
Furnished Items And Quantity:
1 motor controller
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Watertight
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The means used to operate the item.APHE
Operation Method:
Power
MRC:
The distance between flanges on the drum,and the location on the item.ATWD
Drum Flange To Flange Distance And Location:
28.750 inches first drum err-100
MRC:
The distance between flanges on the drum,and the location on the item.ATWD
Drum Flange To Flange Distance And Location:
28.750 inches second drum err-100
MRC:
The length of a straight line which passes through the center of the drum,and terminates at the circumference,and its location on the item.ATWE
Drum Diameter And Location:
20.000 any acceptable meters blank
MRC:
The length of a straight line which passes through the center of the drum,and terminates at the circumference,and its location on the item.ATWE
Drum Diameter And Location:
20.000 any acceptable meters preset
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
The power required to start and operate the item at rated capacity.ATYG
Power Requirement Rating:
25.00 horsepower
MRC:
The design on the drum surface.ATYH
Drum Surface Design:
Grooved
MRC:
A designation by which the drum is identified.AWFA
Drum Designation:
Left-hand
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Any acceptable
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
230.0
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by westinghouse electric motor, dwg no.46-j-878 and westinghouse controller, dwg no. 46-j-602