TXT
묘사:
Reactor-transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
72 single component all winding
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
4.875 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
7.062 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/fpn-6 (32)
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
6 all groupings
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded stud all groupings
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component all winding
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches all groupings
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.04030 inches american wire gage single component all winding
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc all groupings
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead