TXT
묘사:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
27.250 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
36.125 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
28.750 inches
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.5625 inches single end
Step Diameter:
1.6250 inches single end
MRC:
A measurement of the longest dimension of the step,in distinction from width.ABGJ
Step Length:
0.3750 inches single end
MRC:
A measurement of the longest dimension of the tapered portion of an item,in distinction from width.ABND
Taper Length:
2.3750 inches single end
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.5000 inches single end
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.2500 inches single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
2.4365 inches single end
MRC:
A measurement of the longest dimension of a keyway,in distinction from width.AFYS
Keyway Length:
2.3125 inches single end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end or counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof-15 deg
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Natural convection ventilated
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Mil-std-108
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Vertical mounting position
MRC:
The amount of taper measured parallel to the longitudinal axis of the item per specific measurement scale.CQRR
Taper:
0.500 per foot in inches single end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
3.250 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
50.0 operating degrees celsius
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
16.750 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
440.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A2 first style single end and a12 second style single end and a29 third style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 solder lug