TXT
묘사:
Line Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit and 165.0 degrees fahrenheit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
11.330 inches
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Adjustable
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
5.0
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
5.810 inches
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
5000.0 pounds static
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
30.0 seconds on and 1.0 minutes off
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
28.0
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by the source control dwg no.