TXT
묘사:
Electrical Coil Assembly
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.546 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
535 single component all winding
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.171 inches single group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
15.60 millihenries single component all winding
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
5.313 inches
MRC:
The length of a straight line which passes through the center of a mounting bolt circle,and terminates at the circumference.AFFL
Mounting Bolt Circle Diameter:
4.875 inches single mounting facility single center group
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
2 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
6 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical and winding turns single component all winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00708 inches american wire gage single component all winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
0.2 amperes ac single component all winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
36.000 single component all winding
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
100.00 ac volts single component all winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead