MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 15.240 inches and 15.260 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 6.365 inches and 6.385 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
15000.0 feet
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmtsingle 2nd operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts 1st power output-12.0 dc volts 2nd power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-55.0/+100.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc amperes 1st power output and 1.0 dc amperes 1st power output0.0 dc amperes 2nd power output and 2.0 dc amperes 2nd power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single 1st power outputsingle 2nd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
190.0 millivolts peak 1st power output125.0 millivolts peak 2nd power output