Directional Coupler
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.000 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.000 inches
MRC:
The number of complete cycle changes of radiated electromagnetic energy,per unit of time,for which an item is rated.ANKZ
Radio Frequency Rating:
Between 0.325 gigahertz and 1.0 gigahertz
MRC:
Indicates the design type of the item.APGF
Design Type:
Unidirectional
MRC:
Indicates the type of unit.APQB
Unit Type:
Transmission line
MRC:
The maximum to minimum voltage standing wave ratio at a specified frequency/ies/.BGPS
Voltage Standing Wave Ratio At Reference Frequency:
1.05 to 1.0 over frequency range
MRC:
The amount of decrease in power,expressed in decibels.BGPX
Power Loss In Decibels:
40.0
MRC:
The nomenclature by which the terminal fitting is identified.BGPY
Terminal Fitting Name:
Connector
MRC:
The name of the government agency or commercial organization that controls the terminal fitting.BGPZ
Terminal Fitting Controlling Agency:
An
MRC:
An identifying number assigned by the government agency or commercial organization controlling the terminal fitting.BGQB
Terminal Fitting Identifying Number:
Type no. Ug-532a/u; type n
MRC:
An indication of the designed use of the terminal fitting.BGQC
Terminal Fitting Usage Design:
Main line and secondary line