MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Knife blade type
MRC:
The element,compound,or mixture of which the terminal is fabricated.ABDM
Terminal Material:
Copper
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 10.290 inches and 10.470 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
2.250 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.910 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Fiber or ceramic or plastic, melamine, glass filled
MRC:
The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
Continuous Current Rating In Amps:
500.000
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Terminal Width:
Between 1.965 inches and 2.035 inches
MRC:
A measurement of the smallest dimension of the terminal,in distinction from length or width.AFWY
Terminal Thickness:
Between 0.247 inches and 0.253 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
250.0 ac
MRC:
Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
Circuit Over-current Interruption Type:
Time delay
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
Opaque body
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Nonrenewable fusible element
MRC:
The time elapsing before circuit interruption of an item operated at a specified percent of its normal current rating,expressed in seconds.CQPB
Circuit Over-current Interruption Delay Time In Seconds:
12.0 200 pct of current rating and 10.0 500 pct of current rating
MRC:
The maximum rated current at which the item will interrupt or short circuit,expressed in amperes.CSQN
Short-circuit/interrupt Current Rating In Amps:
200000.0
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81348-w-f-1814 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81348-w-f-1814/28 government specification