부품 번호:
vgs-3722-316-pc-st-xx-d024
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Open
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal or vertical
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
175.0 pounds per square inch single response
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
24.0 dc
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Flow function: three way normally open (3/2 n.O.); port size: 1" npt; flow diameter: 1" (25.4 mm); cv: 11.1 (kv 161); seal material: fkm (fluorocarbon); solenoid enclosure: nema 7&9. Class i, div. Ii, grp. A, b - class i, div. I grp. C, d -class ii, div. I, grp. E, f, g; coil entry: 1/2" npt conduit with 24" flying wire leads, not polarity sensitive; inrush & holding: 320 ma; coil resistance: 75 ohms; watts: 7.2
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 316
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Oil, lubricating, diester base single response