부품 정보
Ingersoll rand 10hp 80 gal rotary screw air compressor
TXT
묘사:
Rotary Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
28.000 cubic meters per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
125.000 pounds per square inch gage
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Horizontal tank
MRC:
The mechanical action by which compression takes place.AAYB
Rotary Compressor Design:
Axial screw
MRC:
The volume of the air storage container/s/,including oil storage for rotary designs when applicable.AAYR
Receiver Tank Capacity:
10.69 cubic feet
MRC:
The speed of the compressor required to produce its rated capacity,expressed in revolutions per minute.AAYS
Compressor Speed At Rated Capacity In Rpm:
3500.0
MRC:
A measurement of the longest dimension of an item unencumbered by packaging or packing,in distinction from width.AJAF
Unpackaged Unit Length:
53.800 inches
MRC:
A measurement taken at right angles to the length of an item unencumbered by packaging or packing,in distinction from thickness.AJAG
Unpackaged Unit Width:
29.020 inches
MRC:
A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
Unpackaged Unit Height:
60.660 inches
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
230.0 ac
MRC:
The degree of heat or cold as applied to the function of the item.CSFH
Tempurature Rating Per Function:
36.0 degrees fahrenheit operating
MRC:
The brake power required to start and operate the item including all accessories at the actual rated capacity,expressed in unit of power.CXNT
Brake Power Required:
10.0 horsepower
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Ambient operating temp 36 to 105 f; 80 gal tank