부품 정보
Optional tracer third conductor yellow
TXT
묘사:
Electrical Power Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
60.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.449 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
3
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
65 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
12 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
3 singles
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
300.0 root mean square (rms) operating voltage all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position primary insulation first conductorwhite 1st position primary insulation second conductorgreen 1st position primary insulation third conductorblack 2nd position jacket cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductorsrubber synthetic 1st position primary insulation all conductorsrubber synthetic 2nd position jacket cable