MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass, astm b16-60, 1/2h
First End Flange Outside Diameter:
Between 1.128 inches and 1.131 inches
Second End Flange Outside Diameter:
Between 0.877 inches and 0.881 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Plain face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Round
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Plain face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACLY
Second End Flange Shape Style:
Round
Face To Face Distance:
4.400 inches
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
120.000 inches
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Thermostatic
MRC:
A designation of the evaporator temperature range at which the valve is designed to operate.AFKL
Valve Evaporator Tempurature Range Designation:
Low
MRC:
The means utilized to hold the bulb in position.AFKR
Bulb Mounting Method:
Clamp
MRC:
The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
Refrigeration Capacity In Btu Per Hour:
2.6