부품 번호:
tcln12fw12x58odf10ftee
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
C1 straight thru
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.625 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACMP
Second End Outside Diameter Tube Accommodated:
0.500 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk, top guided
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
120.000 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
5.000 inches
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Thermostatic
MRC:
A designation of the evaporator temperature range at which the valve is designed to operate.AFKL
Valve Evaporator Tempurature Range Designation:
Low
MRC:
An indication of whether or not a device is included that throttles or stops the flow of liquid,gas,and the like,through the valve when evaporator suction pressure reaches the maximum pressure setting.AFKM
Valve Pressure Limiting Device:
Not included
MRC:
Indicates the type of transfer agent contained in the thermostatic bulb which reacts to temperature change.AFKQ
Bulb Media Type:
Refrigerant 12
MRC:
The means utilized to hold the bulb in position.AFKR
Bulb Mounting Method:
Clamp
MRC:
Indicates whether the equalizer location is internal,external,or both.AFKU
Valve Equalizer Location:
External
MRC:
Indicates the type of connection in the valve body for connecting the equalizer line.AFKV
Valve Equalizer Connection Type:
Flared tube
MRC:
The length of a straight line which passes through the center of the valve equalizer connection,and terminates at the circumference.AFKW
Valve Equalizer Connection Diameter:
0.250 inches
MRC:
The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
Refrigeration Capacity In Btu Per Hour:
6.0