부품 번호:
tcle7-12ml58x78odfang5ft2a
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" or "adqn" if flanged one or two ends
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
250.0 degrees fahrenheit
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.875 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACMP
Second End Outside Diameter Tube Accommodated:
0.625 inches
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
60.000 inches
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Thermostatic
MRC:
An indication of whether or not a device is included that throttles or stops the flow of liquid,gas,and the like,through the valve when evaporator suction pressure reaches the maximum pressure setting.AFKM
Valve Pressure Limiting Device:
Not included
MRC:
Indicates whether the equalizer location is internal,external,or both.AFKU
Valve Equalizer Location:
External
MRC:
Indicates the type of connection in the valve body for connecting the equalizer line.AFKV
Valve Equalizer Connection Type:
Flared tube
MRC:
The length of a straight line which passes through the center of the valve equalizer connection,and terminates at the circumference.AFKW
Valve Equalizer Connection Diameter:
0.250 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
SUPP-OR-TEQ-UIPM
MRC:
The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
Refrigeration Capacity In Btu Per Hour:
90.0