MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Steel
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
7.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
11.250 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Fixed stage
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Case
MRC:
Indicates the type of charger furnished.AKWH
Charger Type:
Solid state semiconductor
MRC:
The voltage the unit is designed to deliver,expressed in volts.AKWL
Charging Voltage In Volts:
24.8
MRC:
The current output rating which the item delivers,expressed in amperes.AKWM
Charging Current Rating In Amps:
10.000
MRC:
The means provided for controlling the current output.AKWP
Charging Regulation Method:
Continuous
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Ammeter 1, circuit breaker 1, control module 1, potentiometer 1, power transformer 1, silicon power rectifier 1
MRC:
The number of cells contained in the item.AQGQ
Cell Quantity:
12
MRC:
Indicates the type of battery/ies/ for which the item is designed.AQYH
Battery Type For Which Designed:
Lead-acid
MRC:
The number of alternating current phases.FAAZ
Phase:
Single