부품 정보
This p/n is the standard switch without modifications
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Hole mounted
MRC:
The number of actuators provided in the item for selection of switching positions.AFCG
Switch Actuator Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Roller arm
Housing Height:
1.785 inches
MRC:
A measurement of the longest dimension of the housing,in distinction from width.AFWD
Housing Length:
4.685 inches
MRC:
A measurement taken at right angles to the length of a housing,in distinction from thickness.AFWE
Housing Width:
1.875 inches
Center To Center Distance Between Housing Mounting Facilities Parallel To Length:
2.344 inches
Center To Center Distance Between Housing Mounting Facilities Parallel To Width:
1.158 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
600.0 ac and 240.0 dc
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Bow thruster
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
2 two circuit, double break/double make, one position momentary single switch unit
MRC:
The movement of the switch actuator.CXQQ
Actuator Movement:
Between 18.0 pretravel degrees and 57.0 overtravel degrees and 10.0 differential degrees
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
6.000 amperes resistive ac and 0.150 amperes inductive dc and 0.400 amperes resistive dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 screw