부품 정보
Free reverse flow; 0.500 in. Npt conduit port w/red lead wire; 2 way, 2 position
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
100.0 degrees fahrenheit single response
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.500
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded cartridge all ends
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
16 all ends
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches all ends
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
12.0 dc
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Hydraulic fluid, phosphate-ester base single response
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Un all ends