MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The means of closing the item when inlet pressure decreases.ADSU
Disk Loading Method:
Spring
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
700.0 degrees fahrenheit single response
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Paul-munroe enertech, dual filter assembly, model pd26075-1000
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded cartridge all ends
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal or vertical
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 316 body
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight through drop-in cartridge