MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						A measurement of the longest dimension of a terminal,in distinction from width.ABJT
					 
					
						Terminal Length:
					
					
						10.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						Between 0.636 inches and 0.676 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						0.150 inches 					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended by an item.AEHX
					 
					
						Maximum Power Dissipation Rating:
					
					
						500.00 milliwatts					
				 
							
					
						MRC:
						The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
					 
					
						Ambient Tempurature At Full Rated Power:
					
					
						25.0 degrees celsius					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						125.0 degrees celsius					
				 
							
					
						MRC:
						The time required for the temperature of an item to change 63.2 percent of the difference between its initial and final body temperature when subjected to a temperature change under zero power conditions,expressed in seconds.AEJA
					 
					
						Thermal Time Constant In Seconds:
					
					
						50.0					
				 
							
					
						MRC:
						The ratio,at a specified ambient temperature,of a change in power dissipation in an item to the resultant body temperature change,expressed in milliwatts per degree celsius.AEJB
					 
					
						Power Dissipation Constant In Milliwatts Per Deg Celsius:
					
					
						5.0					
				 
							
					
						MRC:
						The ratio of the rate of change of resistance with temperature to the resistance of the item at a specified temperature,expressed in percent per degree celsius.AEJC
					 
					
						Zero Power Tempurature Coefficient Of Resistance In Percent Per Deg Celsius:
					
					
						29.40					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encapsulated					
				 
							
					
						MRC:
						The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.CQWD
					 
					
						Zero Power Resistance:
					
					
						5.000 kilohms					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.CRQJ
					 
					
						Zero Power Resistance Tolerance In Percent At Reference Temp:
					
					
						-5.0/+5.0					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Probe,  surface mounting					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 wire lead