Wire, 16awg, wht, tfe p/n m16878/4bje9; cable, 4 cond, shld, color brn, red, yel, orn, p/n ss-160329; dwg title cable assembly, power supply 120vac input
TXT
묘사:
Electrical Power Cable Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
120.000 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
200.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.080 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Scope shield ph ii
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector 1st end all conductorsconnector plug 2nd end all conductors
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Power
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
4
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
16 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
29 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
4 singles
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
Ms3108e32-8s 1st end all conductors5965vy 2nd end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
96906 1st end all conductors83315 2nd end all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White 1st position cover all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductorsplastic polytetrafluoroethylene 1st position primary insulation all conductors
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Internal angle and external straight connector