MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.312 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.625 inches
First Flat Length:
0.250 inches single actuator
Flat Height:
0.216 inches single actuator
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.247 inches single actuator and 0.251 inches single actuator
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.562 inches single actuator
MRC:
Indicates the type of device used to prevent physical movement of the item on its mounting surface.AFDC
Nonturn Device Type:
Flatted bushing at 3: 00 o'clock
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing w/panel seal single mounting facility
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.375 inches single mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
115.0 lowest ac voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
28.0 dc at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
300.0 highest ac voltage rating at sea level
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, flatted single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
60.0 degrees single actuator
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
225.0 milliamperes resistive load lowest ac voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
50.0 milliamperes resistive load highest ac voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
500.0 milliamperes resistive load dc at sea level and 50.0 milliamperes inductive load dc at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Circular wafer, bushing mount
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unef single mounting facility