부품 정보
Junction pattern arrangement: pnp
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Plastic
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.210 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.165 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.205 inches
MRC:
An indication of the internal basic form of the item.ALAS
Internal Configuration:
Junction contact
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
The chemical compound or mechanical mixture properties of which the semiconductor is fabricated.CTMZ
Semiconductor Material:
Silicon
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
20.0 collector to base voltage, dc and 20.0 collector to emitter voltage, dc and 3.0 emitter to base voltage, dc
MRC:
The amount of electrical power that can be dissipated and the specific electrical characteristic.CTRD
Power Rating Per Characteristic:
350.0 milliwatts small-signal input power, common-collector preset
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
28480-1853-0352 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 uninsulated wire lead