MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.375 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.375 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.750 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+70.0/+500.0
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
10.0 gravitational units
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
15.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+90.0 degrees celsius
MRC:
The numeric value of the life expectancy of the item.AFHH
Average Life Rating:
50000.0
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Hours
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
50000.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
40000.0 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
0.450 microseconds 1st output channel err-100 and 0.550 microseconds 1st output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
0.450 microseconds 2nd output channel err-100 and 0.550 microseconds 2nd output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
2.160 microseconds 3rd output channel err-100 and 2.640 microseconds 3rd output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
2.160 microseconds 4th output channel err-100 and 2.640 microseconds 4th output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive output channel
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
1200.000 pulses per second 2nd output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
1600.000 pulses per second 1st output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
200.000 pulses per second 4th output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
400.000 pulses per second 3rd output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
15300.000 volts output channel
MRC:
The number of pulses in a group per channel.BHTX
Err Default:
Err default
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Pulse, trigger
MRC:
The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
Shock Pulse Duration Time:
11.0 milliseconds
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
380.0 single voltage and 420.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
108.0 single voltage and 118.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
09691-70344 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)