TXT
묘사:
Telephone Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
12.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
14.000 inches
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
12.0 volts
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Test set, telephone; headset-microphone
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Jetds
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Ts-1323/ptm-7 type no. And h-91a/u type no.
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Test set, telephone
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Type no. An/ptm-7
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Check of cable repeaters, measurement of input and output pulses, dc voltage drop of repeater, cable voltage and current, battery voltage, resistance and capacitance
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Vmeter range 0.033 v to 2.5 v peak-to-peak, 0 to 1000 v dc, 0 to 40 ma dc; order wire, freq response 300 to 1700 cycles, transmit level plus 10 dbm, receive level minus 10 dbm to plus 26 dbm; signalling oscillator, 16 cycles at 17 v rms
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
7.500 inches