MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Irregular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.750 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
1.7 gigahertz single frequency operating and 1.9 gigahertz single frequency operating
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Nontransfer
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/fsq-151
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10 single
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.05 single
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
5.0 kilowatts average single
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
60.0 single
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Motor
MRC:
The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
Actuator Current Type And Rating In Amps:
0.5 dc
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
22.0
MRC:
The time required for switching between any two adjacent positions.AKPP
Switching Time:
1.5 seconds
MRC:
The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
Switch Return Mechanism Type:
Fail-safe
MRC:
Indicates the type of waveguide flange.AKPT
Waveguide Flange Type:
Choke
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
2
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
10 unthreaded hole
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
Connector, receptacle