MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.123 inches and 0.147 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 0.055 inches and 0.065 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
220.0 degrees celsius
MRC:
The ratio,at a specified ambient temperature,of a change in power dissipation in an item to the resultant body temperature change,expressed in milliwatts per degree celsius.AEJB
Power Dissipation Constant In Milliwatts Per Deg Celsius:
2.0
MRC:
The ratio of the rate of change of resistance with temperature to the resistance of the item at a specified temperature,expressed in percent per degree celsius.AEJC
Zero Power Tempurature Coefficient Of Resistance In Percent Per Deg Celsius:
3.31
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
2500.0 ohms 1st resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-10.0 to 10.0 1st resistance-temperature point
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Global hawk asip
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encapsulated
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Tinned dumet contact tabs, glass body, thermal time constant: 8 seconds max