MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
500.0 single high pass pulses per second
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
700.0 single high pass two phase to two phase
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
700.0 hertz 2nd band pass 2nd function
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
10.0 kilohms 1st band pass
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
10.0 kilohms 2nd band pass
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
10.0 kilohms 1st band pass 1st function
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
10.0 kilohms 1st band pass
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
10.0 kilohms 2nd band pass
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
10.0 kilohms 2nd band pass 2nd function
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded hole
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.164 inches
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
425.00 hertz blank and 575.00 hertz blank and 625.00 hertz blank and 775.00 hertz blank