MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.500 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.530 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.270 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.240 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.093 inches
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-10.0 degrees celsius 4th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-20.0 degrees celsius 3rd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-40.0 degrees celsius 2nd resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-5.0 degrees celsius 5th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
-80.0 degrees celsius 1st resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
10.0 degrees celsius 6th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
120.0 degrees celsius 10th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
20.0 degrees celsius 7th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
40.0 degrees celsius 8th resistance-temperature point
MRC:
The temperature levels at which resistance ratings have been established,under zero power condition.AEJD
Tempurature Points For Resistance Readings At Zero Power:
80.0 degrees celsius 9th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
52.11 ohms 10th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
68.33 ohms 9th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
101.95 ohms 5th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
103.9 ohms 4th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
107.79 ohms 3rd resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
115.54 ohms 2nd resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
130.89 ohms 1st resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
84.27 ohms 8th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
92.16 ohms 7th resistance-temperature point
MRC:
The resistance at a selected temperature,under zero power condition.AEJE
Zero Power Resistance At Specificationified Temp:
96.09 ohms 6th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-10.0/+10.0 1st resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-3.5/+3.5 10th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-4.2/+4.2 9th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-5.6/+5.6 7th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-5.9/+5.9 6th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-5.1/+5.1 8th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-6.3/+6.3 5th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-6.5/+6.5 4th resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-6.9/+6.9 3rd resistance-temperature point
MRC:
The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.AEJF
Resistance Tolerance At A Specificationified Tempurature In Percent:
-7.7/+7.7 2nd resistance-temperature point
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encapsulated
MRC:
The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.CQWD
Zero Power Resistance:
100.000 ohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.CRQJ
Zero Power Resistance Tolerance In Percent At Reference Temp:
-10.0/+10.0
MRC:
The temperature at which nominal zero power resistance is specified,expressed in degrees celsius.CTGT
Reference Tempurature In Deg Celsius:
0.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Probe, surface mounting
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead