부품 정보
External protection type and location- chafe guard, polytetrafluoroethylene tubing , inner conveying tube material-plastic, polytetrafluoroethylene
TXT
묘사:
Nonmetallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
3b 1st end
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand 1st end
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
0.602 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit single response and 400.0 degrees fahrenheit single response
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit and 400.0 degrees fahrenheit single response
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
Between 1.030 inches and 1.090 inches
MRC:
The minimum inside bending radius formed without stressing or deformation of a flexible item.ACKH
Minimum Inside Bending Radius:
7.750 inches
MRC:
The specification or standard /industrial or governmental/ that specifically covers the construction of the hose or tubing,excluding the end fittings.ADLF
Hose Or Tubing Specification/std Data:
Sae as604, size 12-81343 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Swivel nut flare 1st end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 1st end
MRC:
The name of the fitting and/or component and the element, compound, or mixture of which it is fabricated.AKXL
End Fitting Component And Material:
Complete fitting steel comp 304 all ends
MRC:
The name of the fitting and/or component and the plating, dip and/or coatingthat cannot be wiped off. plating and/or coating is any chemical and/or metallic additive, electrochemical or mild mechanical process which protects the surface.AKXM
Fitting Component And Surface Treatment:
Complete fitting passivate 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal tube 1st end
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrostatic discharge capability
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
12 1st end
MRC:
Indicates whether or not the second end is identical to the first end.CQBB
Second End Relationship With First End:
Identical
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
12000.0 pounds per square inch
MRC:
An indication of whether or not the end has the capability to rotate.CQBG
First End Swivel Action Capability:
Not included
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
1st layer braided corrosion resistant steel wire err-100
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
2nd layer spirally wrapped corrosion resistant steel fabric err-100
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
3rd layer spirally wrapped corrosion resistant steel fabric err-100
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
4th layer spirally wrapped corrosion resistant steel fabric err-100
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
5th layer spirally wrapped corrosion resistant steel fabric err-100
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer braided corrosion resistant steel wire err-100
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
1st layer braided corrosion resistant steel wire
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
2nd layer spirally wrapped corrosion resistant steel fabric
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
3rd layer spirally wrapped corrosion resistant steel fabric
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
4th layer spirally wrapped corrosion resistant steel fabric
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
5th layer spirally wrapped corrosion resistant steel fabric
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer braided corrosion resistant steel wire
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
1.062 inches 1st end
MRC:
Indicates the type of external protection provided and its location on the item.CQQN
External Protection Type And Location (non-core):
chafe guard, polytetrafluoroethylene tubing
MRC:
The angle of the end surface upon which the mated surface seats.CQRB
Seat Angle:
37.0 degrees 1st end
MRC:
A steady,uniform,internal,static pressure that the item must withstand without leakage,abnormal distortion,or damage.CRDW
Hydrostatic Test Pressure:
6000.0 pounds per square inch
MRC:
The type of protection provided by the outer covering.CRJM
Outer Covering Environmental Protection:
Corrosion resistant
MRC:
The condition of the item with respect to the texture of the inner surface.CRWL
Inside Surface Condition:
Smooth
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
7.500 inches
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unj 1st end
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81343-as627 professional/industrial association standard
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
Sae as604, size 12-81343 national std/spec and 81343-as627 professional/industrial association standard