부품 정보
150 watt single output, pfc, open frame power supplies
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.310 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.970 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.580 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt or two 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
110.0 dc pounds per hour dry 2nd operating power rqmt and 370.0 dc pounds per hour with retaining chain 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
85.0 ac pounds per hour dry 1st operating power rqmt and 265.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
19.2 dc volts single power output and 26.4 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st operating power rqmt and 66.0 hertz 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd operating power rqmt and 66.0 hertz 2nd operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-10.0/+71.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
6.5 dc amperes single power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
2.0 ac amperes 2nd operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
2.0 ac amperes 1st operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Ambient air