부품 번호 RI1AAB1

Push Switch

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
ri1aab1
비무장화:
No
수명:
측정 단위:
NIIN:
010486655
NSN
국가 주식 번호:
5930-01-048-6655 5930010486655
TXT
묘사:
Push Switch
INC
INC
아이템 이름 코드:
00406
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Bushing mounted
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.562 inches
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.625 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.250 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round, flush
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
1.000 inches
MRC:
None.AFUS
Actuator Height:
0.062 inches
MRC:
The hue or tint of the actuator.AFVA
Actuator Color:
Black single actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
600.0 ac
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
16
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
1.125 inches
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, normally open, double make, momentary action single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
10.000 amperes resistive ac
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Un
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw

{lang[cimilar]} Push Switches

« Switches {lang[catalog]}
지금 비교»
맑다 | 숨기다