MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.263 inches
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Relay
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Dc
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Dc
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
22.0
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
8.0 amperes
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
3.2 kilovolts
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Dc
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
26.5
MRC:
The amount of operating current,expressed in amperes.APHB
Operating Current In Amps:
8.0
MRC:
The maximum opposition to the flow of direct current,expressed in ohms.APJX
Maximum Dc Resistance In Ohms:
0.02