TXT
묘사:
Receiver-transmitter Control
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum alloy
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-10.0 to 50.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-40.0 to 70.0 degrees celsius
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
230.0 ac and 24.0 dc
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/urc-11 (v)
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Back
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rack
MRC:
The maximum rated power that an item can safely consume or provide,measured in watts.AZQH
Maximum Wattage Rating In Watts:
40.0
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
1 jack
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
19.000 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
5.250 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
17.250 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Humidi type 95 pct at 50 degrees c; elevation 10000 ft; 100 simplex and/or duplex channels; modes of operation: usb, lsb, am, ame, fm, afsk, cw, 2-isb and 4-isb; scan rate 200/500ms/channel; scanned channels 100 max; phase continuous 8-ary fsk modulation