TXT
묘사:
Nonind Wire Wound Fixed Resistor
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
49.900 ohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-1.000/+1.000
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
25.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
275.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0/+275.0
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Encased
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
0.100
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
Between 0.250 inches and 0.374 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
6.000 free air
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Terminal Width:
0.140 inches
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-prf-39009/2b government specification