부품 정보
11.500 in. By 11.750 in. By 13.250 in. O/a dim.
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 105.0 volts and 125.0 volts and 210.0 volts and 230.0 volts
MRC:
The means by which the item records information.ANBK
Recording Method:
Electrosensitive paper
MRC:
The number of recording channels provided.BKBX
Recording Channel Quantity:
2
MRC:
The minimum and maximum values of the frequency range at which the item will record,expressed in hertz.BKBY
Recording Frequency Range In Hertz:
+0.0/+100.0
MRC:
The amount of responsive departure per volt,expressed in millimeters.BKBZ
Sensitivity Deflection Per Volt In Millimeters:
100.00
MRC:
The rated speed at which the chart is designed to operate.BKCB
Chart Speed:
1.0 millimeters per second and 5.0 millimeters per second and 25.0 millimeters per second and 125.0 millimeters per second
MRC:
The measured amount of departure from the mean position to the extreme at a specified frequency range.BKCC
Amplitude Deflection Frequency Range:
40 mm at 0 to 35 hz; 20 mm at 36 to 70 hz; 10 mm at 71 to 100 hz
MRC:
An indication of whether or not an event marker(s) is provided.BKCD
Event Marker:
Provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Oscillograph, except specially designed